<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-27 23-27-09
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 55 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 68 kHz 14069 0,3412
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,7 dBr 4,54 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 68 kHz MIN: 11 kHz % above 76 kHz: 0,3412 Acquired: 2025/10/27 23.26.05 Total samples: 14069 Equivalent time: 0:11:43 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,9 dBr MIN: 2,7 dBr AVE: 4,54 dBr % above 12,2 dBr: 0,0 Last value: 5,2 dBr (2025/10/27 23.26.05) 23.12 23.14 23.16 23.18 23.20 23.22 23.24 23.26 0 2 4 6 Pm [dBr]